MEGAPOWER CPU 8200-0421-03, REV. G
ADMINISTRATOR’S GUIDE
75 of 82
Manual Clear – This method relies on an
operator clearing it via a keyboard or after the
alarm contact number is called to the monitor. All
alarms remain queued on their respective
monitors until the alarm is manually cleared.
Instant No Ack – This method instantly clears the
alarm when the alarm condition returns to a non-
alarming state. No operator acknowledgement is
permitted.
Auto No Ack – This method clears the alarm
automatically 20 seconds after the alarm
condition returns to a non-alarming state. No
operator acknowledgement is permitted.
Note: If an alarm is armed for more than one
monitor, clearing it on any armed monitor will clear it
from all armed monitors.
If the Dual alarm display is method is used, operators
must call the Hold monitor in order to manually clear
the alarm.