Model AD1273 CobraDome
Indoor Surveillance Unit
Installation and Operation Instructions
This manual describes the installation and maintenance procedures for the American Dynamics Model AD1273 CobraDome
Indoor Surveillance unit. Before installation, become familiar with all of the special features and warnings associated with this
equipment. Once installation is complete, store this manual in a safe, convenient location for future reference.
Vista de pagina 0
1 2 3 4 5 6 ... 55 56

Indice de contenidos

Pagina 1 - Indoor Surveillance Unit

Model AD1273 CobraDome Indoor Surveillance UnitInstallation and Operation InstructionsThis manual describes the installation and maintenance procedure

Pagina 2

SETUP AD12734SETUPThis section describes the required settings for properoperation of the AD1273. Before installing the AD1273,determine the intended

Pagina 3 - DYNAMICS

OFFON12345678S1CHASSISThunbwheel Switch (2)DIP Switch4 5Tens DigitUnits DigitFigure 3 - DIP Switch Setting LocationsAD1273 SETUP5

Pagina 4

Camera Number AssignmentFor individual control of camera pan/tilt functions by a matrixswitching system, an individual camera number must beassigned t

Pagina 5 - Table of Contents

AD1273 SETUP7CHASSIS4 5Tens DigitUnits digitFigure 4 - Camera Identification Thumbwheel Switches

Pagina 6

Dome ConfigurationsWhen using the AD1273 with other domes in a securitysystem, determine the type of configuration that best suits theparticular appli

Pagina 7

Jumper RemovalTo remove the J2 jumper from the AD1273 printed circuitboard:1) Disconnect all data, video, and power connections from thedome.2) Remove

Pagina 8

CONNECTIONS AD127310CONNECTIONSData Line Connections Data line connections to the AD1273 are made with user-supplied, 2-wire twisted pair, shielded, B

Pagina 9 - CHASSIS HOUSING

11Power ConnectionsThe 24VAC power lines enter the AD1273 through a 7-pinPlug and Ramp connector (see Figure 9). The 7-pin Rampconnector is mounted t

Pagina 10

12INSTALLATION AD1273INSTALLATIONDrop Ceiling MountThe weight of the AD1273 unit requires additional support ofthe dropped ceiling grid. This additi

Pagina 11 - AD1273 SETUP

AD1273 INSTALLATION13Building FrameSafetyChainChassisHousing Safety WiresSafety WiresDrop Ceiling Tileor2 ft. x 2 ft. Custom TileDropCeiling GridRunne

Pagina 12

The software/firmware furnished with this equipment is confidential to, and copyrighted by, AMERICAN DYNAMICS. It isnot to be copied or disclosed in

Pagina 13 - Units digit

INSTALLATION AD127314Direct and Remote Hard MountDirect hard mounting refers to bolting the AD1273 housingdirectly to a ceiling. Remote hard mounting

Pagina 14

Figure 14 - Remote Chassis Housing-to-Ceiling Hard MountExisting CeilingIncoming Data, Video, and24VAC Power HarnessIncoming Data, Video, and 24VAC Po

Pagina 15

Pendant MountMounting the AD1273 in a pendant configuration requiresusing a pipe flange bolted to the chassis housing, a length ofpipe determined by t

Pagina 16

Mounting SurfaceIncoming Data,Video, and 24VAC Power HarnessSafety CablePendant Shroud *Pendant ShroudFascia Plate *1 1/4" Mounting Pipe(User su

Pagina 17

INSTALLATION AD127318Chassis InstallationPrior to installing the chassis in the chassis housing, set the 8-position DIP switch and the camera number t

Pagina 18

Chassis(Only the Frame is Shown for Clarity)Squeeze togetherSqueeze togetherDetail A: Chassis Mounting Pin Positive EngagementMounting Pin SocketMount

Pagina 19 - Trim Ring

INSTALLATION AD1273Lower Dome InstallationAlign the viewing port (clear area) of the lower dome with thecamera lens.NOTE: Prevent fingerprints accumul

Pagina 20 - Chassis Housing

21Fascia Plate Installation1) Push the plastic safety lanyard attached to the fascia plateinto the lanyard tab slot on the chassis frame. The tab mu

Pagina 21

INSTALLATION AD127322Pendant Shroud InstallationThis procedure applies only to pendant installations using thependant shroud. These instructions comp

Pagina 22

23AD1273 INSTALLATIONMounting SurfacePendant ShroudFascia Plate *Pendant Shroud *Machine Screws (4)ChassisHousingCompletedInstallationFigure 19 - Pe

Pagina 23 - Detail A

The installation of this product should be made by qualifiedservice personnel and should conform to all local codes.QA301CWarning: This product gener

Pagina 24

OPERATION AD1273OPERATIONThe AD1273 Series dome uses AD Manchester Control Codefor pan/tilt positioning, camera zoom, camera focus, and lensiris funct

Pagina 25 - Side View

AD1273 OPERATION25ENTER6 41234567890CLEARAUXILIARYIRISFOCUSZOOMENTEREXITPAGEPAGEOFF ONCLOSE OPENNEAR FARW ID E TE LECAMERA1 0 2 4LAST B-PAS ACKNEXT RU

Pagina 26

OPERATION AD1273Special CommandsThe following is a list of special AD Manchester Control Codecommands available to the AD1273.RESET DOME - (65 CALL th

Pagina 27

27Keyboard Command1 - 64 Set Shot1 - 64 Call Shot65 Call, then, 65 Set66 Call, then, 66 Set67 Set67 Call68 Call69 Call68 Set71 Call, then, 69 Set70 Se

Pagina 28

ADJUSTMENTS AD127328ADJUSTMENTSBacklash AdjustmentProper backlash adjustment eliminates any apparent videoimage hesitation during a slow pan rotation

Pagina 29

29ChassisCameraHousingPan GearPan Gear BevelPan AxisDrive MotorPan MotorDrive Gear Pan AxisDrive Gear#73 Twist DrillPan MotorMounting BracketFigure 2

Pagina 30

30Lens Tracking AdjustmentWhen connected to a monitor, the image generated by theCobraDome camera must stay in focus during transitions fromtelephoto

Pagina 31 - AD1678CM

31AD1273 ADJUSTMENTSCamera LensFocus RingLens TrackingAdjustment WheelTilt AxisDrive GearCobraDomeChassisPan AxisDrive GearCameraLens Frame8-Position

Pagina 33

Appendix

Pagina 36

18 AWG Twisted Pair, Shielded,Belden 8760 or EquivalentNOTE: These Connections Are Typical of One Data Distribution UnitWBSSWBACTP800212 VOLTS AC10 VA

Pagina 38

AD2150 Matrix ControllerRS232 PORTS123KEYBOARDS2345CAMERASALARMS RELAYS 120V60HzCODEBWS BWS BWSMONITORS123452 4 6 8 10 12 14 16 18 20 22 24 26

Pagina 40

AD1996 System CPU POR TS120V60HzDATA LINE12PROG MON1234 567 8910AD2091 Matrix ControllerB W S B W S B W S B W SDATA LINEINOUTINOUT12CODESELEC T12PW

Pagina 41 - AD1273 CobraDome

CAMERA NUMBER SEQUENCEA4Camera SwitchNumber SettingTens Units1 0 1 Group 12 0 2 Group 13 0 3 Group 14 0 4 Group 15 0 5 Group 16 0 6 Group 17 0 7 Group

Pagina 42

CAMERA NUMBER SEQUENCEA5Camera SwitchNumber SettingTens Units257 0 1 Group 5258 0 2 Group 5259 0 3 Group 5260 0 4 Group 5261 0 5 Group 5262 0 6 Group

Pagina 43 - TYPICAL SYSTEM CONNECTIONS

CAMERA NUMBER SEQUENCEA6Camera SwitchNumber SettingTens Units385 0 1 Group 7386 0 2 Group 7387 0 3 Group 7388 0 4 Group 7389 0 5 Group 7390 0 6 Group

Pagina 44

CAMERA NUMBER SEQUENCEA7Camera SwitchNumber SettingTens Units577 0 1 Group 10578 0 2 Group 10579 0 3 Group 10580 0 4 Group 10581 0 5 Group 10582 0 6 G

Pagina 45

Table of ContentsDESCRIPTION ... 1ROUTINE M

Pagina 46

CAMERA NUMBER SEQUENCEA8Camera SwitchNumber SettingTens Units641 0 1 Group 11642 0 2 Group 11643 0 3 Group 11644 0 4 Group 11645 0 5 Group 11646 0 6 G

Pagina 47

CAMERA NUMBER SEQUENCEA9Camera SwitchNumber SettingTens Units769 0 1 Group 13770 0 2 Group 13771 0 3 Group 13772 0 4 Group 13773 0 5 Group 13774 0 6 G

Pagina 48

Camera SwitchNumber SettingTens Units961 0 1 Group 16962 0 2 Group 16963 0 3 Group 16964 0 4 Group 16965 0 5 Group 16966 0 6 Group 16967 0 7 Group 169

Pagina 49

PROBLEM CHECKLISTUnit does not respond to power-up tests Check that 24VAC is connected to pins 3 & 5 of 7-pin connectorAfter power on tests, unit

Pagina 50

ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Backlash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 51

9.65"/245 mm11.25"/285.75 mm 4.5"114.3 mm24"/609.6 mm10.9"/277 mmDIMENSIONSA13

Pagina 52

MODELS:AD1273/B10C: Smoked Dome, B/W camera, 10X zoomlens, for drop or hard ceiling mountAD1273/C10C: Smoked Dome, Color Camera, 10xZoom Lens, for dro

Pagina 54

AD1273 DESCRIPTIONDESCRIPTIONThe AD1273 CobraDome Indoor Surveillance unit is designedfor applications requiring a precision, high-speed pan/tiltmecha

Pagina 55

COMPONENT IDENTIFICATIONCHASSIS HOUSINGThe CHASSIS HOUSING contains the major componentsof the AD1273 CobraDome. Also, all mounting hardware isattache

Pagina 56 - October1995 Printed in U.S.A

3AD1273 COMPONENT IDENTIFICATIONBNC ConnectorFascia MountingSnap Receptacle (4)Chassis to Housing Mounting Pin (2 each side)Lower Dome Mounting Snap