42 INSTALLATION AND SERVICE GUIDE
DeltaDome Programmable Surveillance Camer
a
8000-2616-01, REV.
D
CAUTIONS
For indoor domes, the maximum length of
power cable allowed between the Class 2 LPS
(low voltage) ac source, such as a J-box, and
the dome is 250m (820').
Do not run data and power cables adjacent to
or in the same conduit as line voltage mains
power.
SensorNet 485 networks require 22 AWG
unshielded
cable. Do not exceed 32 devices
per cable run.
RS422 networks require 22 AWG shielded
cable. Do not exceed 10 devices per cable run.
Manchester networks require 18 AWG shielded
cable. Do not exceed 3 devices per cable run.
Always terminate the camera dome connected
at the end of a cable run.
When using the ADPTB base and wiring cables
directly to the dome, ALWAYS connect the
video cable to the dome before you connect the
9-pin cable (which contains power). If you
connect the 9-pin cable first, you risk shorting
delicate electronics near the connector.
I/O PC board (when used).
- If a cable clamp is on this board, remove it,
as it could damage cable connectors in the
housing during assembly.
- Use a jeweler’s 2.5mm (0.1") slotted
screwdriver to tighten connector screws. Do
not overtighten these screws.
- Use the dust cover when shipping the I/O
board back to the manufacturer. It will
protect the spring-finger connector.
When connecting the housing and eyeball
assembly to an outdoor housing:
- Remove both
slot covers to keep the
camera from overheating.
- Keep cables entering the housing away from
the heater assembly.
- Place tubing around the BNC connectors to
avoid shorting their metal surface to the
outdoor housing.
- Check heater fans. Both fans must be on to
prevent overheating.
Note: For further information, see installation
instructions shipped with the outdoor housing.
If disassembling the dome:
- Dome contains electrostatic-sensitive
devices! Use a ground strap when handling
PC boards.
- Once disassembled, parts of housing and
eyeball assembly are “extremely fragile” and
may break. Proceed using extreme care!