American Dynamics RAS916LS-1 Guía de instalación Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 6
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
ADSDU8IOB / ADSDU8IOBW MOUNTING BASE 8200-0600-04, REV. A
INSTALLATION GUIDE
5 of 6
SensorNet data connections
Pin Color Designation
1-4 — Not used.
5 Orange SensorNet (unshielded)
6 Yellow SensorNet (unshielded)
4. Connect twisted pair wires, if used, to connector
TB5.
Pin Designation
1 Video
2 Video Ground
Figure 4. Electrical connections
5. Connect the alarm output cable, if used, to the
TB2 connector.
Pin Color Designation
1 — 12Vdc (100mA max.)
2 — 12Vdc (100mA max.)
3 Output 1 (40mA sync. max.)
4 Output 2 (40mA sync. max.)
5 Output 3 (40mA sync. max.)
6 — Ground
6. Connect the alarm input cable, if used, to the
TB3 connector.
Pin Color Designation
1 Alarm 1 input (3.5mA sink)
2 Alarm 2 input (3.5mA sink)
3 Alarm 3 input (3.5mA sink)
4 Alarm 4 input (3.5mA sink)
5 — Ground
6 — Ground
7. Connect power to the TB4 connector.
Pin Color Designation
1 Black 24Vac
2 Red Ground
3 White 24Vac
8. Reattach the I/O board.
9. Connect power to the base.
RS-422 Data,
SensorNet Data,
Manchester Data
Alarm
Inputs
Power
Video
Twisted
Pair
Video
BNC
Termination
Jumper
Alarm
Outputs
Vista de pagina 4
1 2 3 4 5 6

Comentarios a estos manuales

Sin comentarios