AD Manchester Control Code Connections
AD Manchester Control Code output for AD1640/1680 series
Receivers, Code Distributors, Code Followers/Responders,
Code Translators, and other code-controlled accessories is
provided by the AD2150. Only Receivers designed for AD
Manchester Control Code input are connected in this manner
(e.g., AD1641M, AD1686B).
The AD2150 provides four sets of output code lines, each with
B (Black), W (White), and S (Shield) terminals, on the rear
panel “CODE” connector (see Figure 1-1, page 1-3). Each
code line can accommodate a maximum of three pieces of
equipment in a “Daisy Chain” configuration of less than 5000
feet, as illustrated in Figure 1-3. A 120-ohm termination must
be provided on the last piece of equipment on the line in a
Daisy Chain connection only.
If additional pieces of equipment are required for a Control
Code Output, or if longer distances are involved, Code
Distribution Units must be used, as shown in Figure 1-4. The
AD1691 Code Distribution Unit provides 64 Control Code
outputs from a single Control Code input. A 120-ohm
termination must be provided at the last unit on each code
output line.
The Code Line connections are made with user supplied,
shielded 2-wire twisted pair, Belden 8760 or equivalent (for
plenum use Belden 88760 or equivalent). The maximum code
line length is 5000 feet. To comply with local codes, i.e.,
zoning, code lines are NEC Class 2, power limited, low-
voltage circuits. Where possible, avoid installation near high-
voltage circuits or other potential interference sources.
Connections are made by inserting the appropriate signal wires
into any B/W/S set of the AD2150 CODE connector. A
mating 12-pin screw-terminal connector is provided.
- Insert the Black Code wire into the terminal marked B.
- Insert the White Code wire into the terminal marked W.
- Insert the cable shield into the terminal marked S.
For installation of code-controlled accessories, such as
AD1680/1640 Series Receivers, Code Followers/Responders,
and Code Distribution units, refer to the installation manual
included with each device.
INSTALLATION
Figure 1-3 - Code Line “Daisy Chain” Connections
Comentarios a estos manuales