American Dynamics AD1686B Instrucciones de operaciones Pagina 31

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 30
SET SYSTEM TOURS
Set System Tours permits programming of 24 System Tours.
A System Tour is a programmed sequence of camera(s) which
has assigned dwell times, presets, auxiliaries, and connect next
designations. Each System Tour includes 64 entries. Each
entry contains a slot for camera number, dwell time, presets,
auxiliary action, and connect next.
When SET SYSTEM TOURS is selected from the System
Menu (above), the following menu is displayed. This menu
has eight pages with eight tour entries per page. See page 4-3
for menu paging instructions.
TOUR The TOUR line of this menu identifies the System
Tour number (1-24) for programming. Each System Tour is
called up and programmed separately.
ENT (Entry) Each of the 64 entries in the table identifies a
camera number, dwell time, preset number, auxiliary number,
and a connect next. Each tour entry is unique and the same
camera (with different dwell times, presets, etc.) may be
entered as many times as required.
CAM (Camera) This field establishes the camera number to
be associated with the entry. If the CN field of an entry is set
to “S”, the CAM value is associated with a defined System
Salvo (page 4-7).
DWL (Dwell Time) The dwell time or length of time the
camera is displayed on the monitor is set in this field for each
tour entry. The dwell time may be from 1 to 60 seconds. An
entry of 61 HOLDs the current camera displayed.
PRE (Preset) If the camera is equipped with motorized pan/tilt
and lens with feedback potentiometers, automatic preset scenes
may be defined (page 3-5). If presets have been defined, the
preset scene specified in this entry is called automatically
when the camera associated with that entry is displayed during
a tour. If a preset is not desired, enter a zero.
AUX (Auxiliary) If the camera site is equipped with a
Receiver that has Auxiliary relays, an auxiliary can be
activated automatically during a tour. See the auxiliary setup
instructions in the associated Receiver manual. If no auxiliary
action is desired, enter a zero.
CN (Connect Next) Connect Next selects the next camera in
the table for simultaneous callup to the next contiguous
monitor, thereby forming a “Scratch Pad” Salvo call. A salvo
simultaneously calls up a set of cameras for the dwell time
specified by the first camera entry. The CN settings are:
N=no (select next tour entry after the specified dwell time).
Y=yes (connect to next tour entry as a salvo).
S=salvo (call a System Salvo for the specified dwell time).
PREVIOUS MENU Selecting this menu entry returns to the
SYSTEM menu.
To operate a System Tour (see page 2-5)
1. Select the monitor on which to display the tour.
2. Enter the System Tour number (1-24).
3. Press RUN button.
4. Press ACK button within three seconds.
or
To automatically run a System Tour based on the time of day
and day of week, see SET EVENT TIMERS menu, page 4-9.
4-5
MENU PROGRAMMING - SYSTEM MENU
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
RETURN MAIN
SET SYSTEM TOURS
TOUR - 01
ENT CAM DWL PRE AUX CN
01 0001 02 01 1 ON N
02 0002 02 02 2 ON N
03 0003 02 03 3 ON N
04 0004 02 04 4 ON N
05 0005 02 05 1 OFF N
06 0006 02 06 2 OFF N
07 0007 02 07 3 OFF N
08 0008 02 08 0 N
PREVIOUS MENU