SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME 8200-0184-14, REV. A
INSTALLATION AND SERVICE GUIDE
19 of 37
10. Set the dome address (
Figure 19).
Figure 19. Setting address switches
090909
MSB
LSB
SW3
SW1SW2
Use the following addresses for the protocols
shown:
PROTOCOL SW3 SW2 SW1
AD Manchester,
Range: 001—064
0 x x
PELCO "P," 4800 baud
RS-422, Range: 001—099
0 x x
Sensormatic, 4800 baud
RS-422, Range: 001—063,
065—099
0 x x
Sensormatic, RS-422
Address 64 is used for global
broadcasts
0 6 4
SensorNet,
Range: 001—099
0 x x
VICON, 4800 baud RS-422,
Range: 001—099
0 x x
1 x x
SensorNet,
Range: 100—254
2 x x
Address 255 is used for
global broadcasts
2 5 5
Dept. of Transportation
(NTCIP), 4800 baud RS-422,
Range: 301—399
3 x x
Dept. of Transportation
(NTCIP), 9600 baud RS-422,
Range: 401—499
4 x x
Dept. of Transportation
(NTCIP), 19.2K baud RS-422,
Range: 501—599
5 x x
PROTOCOL SW3 SW2 SW1
PELCO "P," 2400 baud
RS-422, Range: 601—699
6 x x
PELCO "P," 9600 baud
RS-422, Range: 701—799
7 x x
Reset HITACHI VK-xxxx(E)R
camera block from 38.4K to
4800 baud (SpeedDome Ultra
VII WITH EIS 0100+ feature
only).
8 3 0
PANASONIC UTC
8 9 0
Tyco UTC
8 9 1
PELCO UTC (Origins,
Standard, & Extended)
8 9 3
RS-422, LED diagnostic
mode for dome wiring
installations without the I/O
Board
9 0 0
Manufacturing Use,
Range: 901—999
9 x x
11. Connect the housing and eyeball assembly to
the base (
Figure 20).
a. Align the Cap and Base tabs, then turn
clockwise until you hear a click.
12. Wait a few seconds for dome to begin its
homing routine. The homing routine indicates
that the address was placed into the dome
memory and that the dome is ready for
programming.
Figure 20. Connecting housing and eyeball
assembly to base
Note: Align tabs
on Cap and
Base.
Turn clockwise
to latch