SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F
CONTINUATION OF INSTALLATION GUIDE
16 of 18
Electrical
Power Line
Input voltage...................... 24–30Vac, Class 2 LPS
Design tolerance ..................................... 16–36Vac
Line frequency............................................ 50/60Hz
Power consumption................................. 15W max.
Power on inrush current ...................................... 3A
Allowable drop out:..........................................33ms
Connector:................................... Plug-in Euro-style
terminal block 5.08mm
Max. cable distance...........250m from Junction Box
using composite cable
Surge Protection
Video output gas discharge tube rated at:
• 8/20µs impulse discharge current: 10kA
Ten 8/20µs impulses discharge current: 5kA
3.9ohm series resistors
• Low capacitance Zener suppressor 6.5V
1500W
Power line gas discharge tube impulse rated at:
• 8/20µs impulse discharge current: 10kA
• Ten 8/20µs impulses discharge current: 5kA
• TVS rated at 60V, 250A, 1.5 Joules, 8/20µs
impulse
SensorNet/Manchester gas discharge tube impulse
rated at:
• 8/20µs impulse discharge current: 10kA
• Ten 8/20µs impulses discharge current: 5kA
• Isolation transformer coupled, 2000Vrms
• PTC resettable fuse protects transformer
• TVS rated at 5.6V, 40A, 0.1 Joules, 8/20µs
impulse
EIA-422 comm. gas discharge tube impulse rated
at:
• 8/20µs Impulse Discharge Current: 10kA
• Ten 8/20µs Impulses Discharge Current: 5kA
• 33 ohm series resistors
• TVS rated at 5.6V, 40A, 0.1 Joules, 8/20µs
impulse
Alarm input gas discharge tube impulse rated at:
• 8/20µs Impulse Discharge Current: 10kA
• Ten 8/20µs Impulses Discharge Current: 5kA
• 33 ohm series resistors
• TVS rated at 5.6V, 40A, 0.1 Joules, 8/20µs
impulse
Relay output.........................................1kV isolation
SensorNet Communications
Network distance .............................................. 1km
Maximum loads........................................... 32/node
Cable topologies ................................... Daisy chain
Backbone
Star
Wire configuration.... Single unshielded twisted pair
UTP 22AWG non-polarized
Connector: .................................. Plug-in Euro-style
terminal block 3.81mm
Terminating resistor ...120 ohms, switch selectable
EIA-422 Communications
Network Distance.............................................. 1km
Maximum Loads.......................................... 10/node
Cable topologies ................................... Daisy chain
Star
Wire configuration......... Two twisted pairs 22AWG,
polarized, shielded
Connector ................................... Plug-in Euro-style
terminal block 3.81mm
Manchester Communications
Cable topology...................................... Daisy chain
Wire configuration........ Single twisted pair 18AWG
(Belden 8760), polarized, shielded
Connector ................................... Plug-in Euro-style
terminal block 3.81mm
Terminating resistor ...120 ohms, switch selectable