SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F
CONTINUATION OF INSTALLATION GUIDE
9 of 18
Worst-Case Meters
Low Line V (Feet)
117 130 (425)
100 80 (250)
90 60 (200)
117 160 (525)
100 100 (325)
90 60 (200)
117 160 (525)
100 100 (325)
90 80 (250)
240 160 (525)
200 100 (325)
180 80 (250)
117 210 (675)
100 130 (425)
90 80 (250)
240 210 (675)
200 130 (425)
180 80 (250)
117 200 (625)
100 130 (425)
90 100 (325)
240 225 (750)
200 160 (525)
180 125 (375)
117 130 (425)
100 100 (325)
90 60 (200)
240 160 (525)
200 100 (325)
180 80 (250)
0300-0914-03
Universal Transformer
Indoor Dome
AC Power Source
RJ860AP
10-position RS 422
RJ1SNUD, RS856UD
1-position SensorNet
or RS 422 J-Box
28 VA
Transformer
Indoor 240V/50Hz J-Box
RJ860AP1
RJ1SNUD-1, RS856UD-1
10-position RS 422
Indoor 120V/60Hz J-Box
RJ6SN
6-position SensorNet
5604-0006-01
50 VA
Transformer
5604-0044-01
1-position SensorNet
or RS 422 J-Box
Indoor J-Box
Power Cable Requirements: Outdoor Dome
The following table shows the maximum cable
distance between the outdoor SpeedDome Optima
and the 1-position and 6-position (see Note below)
junction boxes, for several worst-case low line
voltages. The distances are shown for 18, 16 and
14
AWG ac power cabling. 14 AWG is larger than
18
AWG and has lower resistance; thus the 14 AWG
has a larger current capacity and supports a longer
cable distance.
Worst-
Case Line
Voltages
18 AWG
16 AWG
14 AWG
90 Vac 30m (100ft) 50m (160ft) 80m (260ft)
102 Vac 60m (200ft) 100m (320ft) 160m (520ft)
180 Vac 30m (100ft) 50m (160ft) 80m (260ft)
204 Vac 60m (200ft) 100m (320ft) 160m (520ft)
Note: The 6-position SensorNet junction box
RJ6SN can power two Outdoor SpeedDome
Optimas or SpeedDome Ultras. However, this
6-position junction box has two banks, one for
dome positions 1, 2, and 3, and a second bank for
positions 4, 5, and 6. If the junction box is used to
power an outdoor dome, no other dome can be
powered from the same bank.
Synchronizing Domes
To prevent picture rolling when switching from
camera to camera, all domes can be synchronized
to a 50Hz or 60Hz ac source. A V-phase
adjustment at the control console enables the
dome to sync to any line phase.