SPEEDDOME OPTIMA HOUSING 8000-2692-01, REV. F
CONTINUATION OF INSTALLATION GUIDE
17 of 18
Alarm Input
Provides signal input to dome alarm.
Connector.................................... Plug-in Euro-style
terminal block 3.81mm
Relay Output
Provides contact closure output from dome output.
Contact type ..............................Form 1-C, NO, NC,
and common connections
Isolation ............................................................. 1kV
Contact material ..................... Gold-clad silver alloy
Contact rating .............................. 30Vac or Vdc, 1A
Connector.................................... Plug-in Euro-style
terminal block 3.81mm
Mechanical
Housing diameter ............................. 190mm (7.5in)
Bubble diameter ............................... 178mm (7.0in)
Housing height (above ceiling)....... 210mm (8.26in)
Bubble depth (below ceiling) .............. 94mm (3.7in)
Pipe connection...............................1.5in NPT Male
Environmental Specifications
Operating temperature:
Indoor .......................................... –10°C to 50°C
(14°F to 122°F)
Outdoor........................................ –40°C to 50°C
(–40°F to 122°F)
Humidity..............................0–95% non-condensing
Storage temperature ........................ –20°C to 65°C
(–4°F to 149°F)