10. Set the dome address (
Figure 18).
Figure 18. Setting address switches
090909
MSB
LSB
SW3
SW1SW2
Use the following addresses for the protocols
shown:
PROTOCOL SW3 SW2 SW1
AD Manchester,
Range: 001—064
0 x x
PELCO "P," 4800 baud
RS-422, Range: 001—099
0 x x
Sensormatic, 4800 baud
RS-422, Range: 001—063,
065—099
0 x x
Sensormatic, RS-422
Address 64 is used for global
broadcasts
0 6 4
SensorNet,
Range: 001—099
0 x x
VICON, 4800 baud RS-422,
Range: 001—099
0 x x
1 x x
SensorNet,
Range: 100—254
2 x x
Address 255 is used for
global broadcasts
2 5 5
Dept. of Transportation
(NTCIP), 4800 baud RS-422,
Range: 301—399
3 x x
Dept. of Transportation
(NTCIP), 9600 baud RS-422,
Range: 401—499
4 x x
Dept. of Transportation
(NTCIP), 19.2K baud RS-422,
Range: 501—599
5 x x
PROTOCOL SW3 SW2 SW1
PELCO "P," 2400 baud
RS-422, Range: 601—699
6 x x
PELCO "P," 9600 baud
RS-422, Range: 701—799
7 x x
Reset HITACHI VK-xxxx(E)R
camera block from 38.4K to
4800 baud (SpeedDome Ultra
VIIE 0100+ feature only).
8 3 0
PANASONIC UTC
8 9 0
Tyco UTC
8 9 1
PELCO UTC (Origins,
Standard, & Extended)
8 9 3
RS-422, LED diagnostic
mode for dome wiring
installations without the I/O
Board
9 0 0
Manufacturing Use,
Range: 901—999
9 x x
11. Connect the housing and eyeball assembly to
the base (
Figure 19) by aligning the Cap and
Base tabs and then turning clockwise until you
hear a click.
Figure 19. Connecting housing and eyeball
assembly to base (cables and
lanyard not shown)
12. Wait a few seconds for dome to begin its
homing routine. The homing routine indicates
that the address was placed into the dome
memory and that the dome is ready for
programming.
Align tabs on
Cap and Base.
Turn clockwise
to latch