Connection and Setup of the AD2079 2-9
ROM Checksum Test
In this test a software checksum of the ROM contents is calculated for comparison with a known
checksum value. The known value is printed on a label on the AD2079 microprocessor. The label
is visible on the bottom of the unit, adjacent to the test switch button.
When the test is run, the CAMERA display shows the checksum message CS =, and the ENTER
display shows the four digit computed value of the checksum. Verify that the displayed checksum
value matches the checksum printed on the label.
When the ROM checksum test is completed, the built-in test sequence will return to the speaker
test when the test switch button is pressed.
To exit the built-in test mode, unplug the wall transformer, remove the test jumper from the dual
terminal block, return the jumpers to their original positions, re-connect to the system, and then re-
plug the transformer.