AD2079 Operator's Manual
1-2
USER
F1
F2
SITE
ARM
PROG
LAST
ACK
NEXT
RUN
HOLD
SALVO
CAMERA
1
4
7
23
5
6
8
9
0
CLEAR
OFF
ON
CLOSE
OPEN
NEAR FAR
WIDE
TELE
SHOT
PATRN
MENU
MONITOR
SITE MONITOR
CAMERA
ENTER
CONTROL
AUXILARY
ZOOM
FOCUS
IRIS
LOCK
OPERATE
PROGRAM
OFF
AD2079 Keyboard Overview
The AD2079 keyboard is comprised of the following elements:
A.
Site Display
- shows the number of the site entered with the
keypad when the
SITE
key
(Ak)
is pressed.
11.
SALVO
key
- calls a specified salvo whose number is
entered on the numeric keypad.
B.
Monitor Display
- shows the number of the monitor entered
with the keypad when the
MONITOR key
(Bk)
is pressed.
12.
CLEAR key
- clears data entered on the numeric keypad
C.
Camera Display
- shows the number of the camera entered
with the keypad when the
CAMERA
key
(Ck)
is pressed.
13.
RUN key
- runs system and scratch-pad tours.
D.
Enter Display
- shows the number entered on the
NUMERIC KEYPAD
(Dk)
.
14.
ACK key
- Acknowledges alarms, runs tours, sets and
repeats patterns.
DUAL FUNCTION KEYS
1.
Keyswitch
- enables the user to switch to the
Operate
,
Program
, or
Menu
modes of operation.
When the keyswitch
is set to
Menu
position, the secondary functions of the
dual function keys
are activated.
15.
OFF/Page Left key
- turns off auxiliary device in Operate
mode. Displays page to left in Menu mode.
2.
Joystick
- enables the user to pan, tilt, zoom and flip the
camera under keyboard control.
16.
ON/Page Right key
- turns on auxiliary device in
Operate
mode. Displays page to right in
Menu
mode.
3.
PROG key
- enables the user to set scratch-pad tours and
patterns, as well as a number of other switching system
functions.
17.
CLOSE/Page Up
key
- closes camera iris in
Operate
mode.
Displays prior page up in
Menu
mode.
4.
ARM & OFF keys
- enables the user to arm and disarm
monitors for alarm display.
18.
OPEN/Page Down
key
- Opens camera iris in
Operate
mode. Displays next menu page down in
Menu
mode.
5.
USER
key
- used to log off a user from a system keyboard. 19.
NEAR/Left Arrow key
- Adjusts focus of near objects in
Operate
mode. Moves cursor left one character in
Menu
mode
6.
F1
&
F2 keys
- special functions keys used to implement
basic system commands and SpeedDome control
20.
FAR/Right Arrow key
- Adjusts focus of distant objects in
Operate
mode. Moves cursor right one character in
Menu
mode
7.
LAST key
- calls the prior camera displayed in a sequence
(tour).
21.
WIDE/Up Arrow key
- Zooms out for wide angle view in
Operate
mode. Moves cursor up one character in
Menu
mode.
8.
NEXT key
- calls the next camera displayed in a sequence
(tour).
22.
TELE/Down Arrow key
-Zooms in for telephoto view in
Operate
mode. Moves cursor down one character in
Menu
mode
9.
HOLD key
- Holds the current camera in a sequence (tour). 23.
SHOT/Enter
key
- Calls presets in Operate mode. Sets
presets in Program mode. Stores entered menu data.
10.
LOCK key
- a toggle key that locks or unlocks camera
control for other keyboard operators.
24.
PATRN/Exit
key
- runs and repeats patterns in Operate
mode. Sets patterns in Program mode. Exits Menu mode.
Bk
13
8
11
13
Ck
9
12
21
19
22
20
2
18
24
23
17
16
15
Dk
D
14
10
C
7
B
4
A
6
Ak
5
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com