SET SYSTEM SALVOS
A System Salvo is a group of LOCAL cameras that can be
called simultaneously to a contiguous group of monitors. A
salvo can be called by keyboard commands, from a System
Tour, from another System Salvo, or on alarm receipt when
included in an Alarm Contact setup. The SET SYSTEM
SALVOS menu permits programming of 64 separate System
Salvos. The maximum number of cameras in a System Salvo
is 16. System Salvos can be nested within other System
Salvos.
The SYSTEM SALVOS menu has one page, with 16 camera
positions included in the page. Set System Salvos is a
LOCAL programming feature.
The salvo being programmed is identified by the SALVO line
below the title line of the menu.
POS (Position) - The salvo Position refers to the order of the
cameras displayed on the contiguous monitors. Each position
of the salvo identifies a camera with an optional preset scene
and auxiliary action for this camera.
For Example: If a System Salvo containing six cameras is
called to monitor 11, the first salvo (position) camera is
shown on monitor 11, the second camera on monitor 12,
and so on, up to the last camera on monitor 16.
CAM (Camera) - A camera number is associated with each
salvo position. This camera is displayed on the next
contiguous monitor. If the CN field is “S”, the CAM entry is
associated with another System Salvo, and the Camera number
is a System Salvo number (a nested Salvo).
PRE (Preset) - If the camera site is programmed for preset
scenes (see page 3-4) a preset scene, from 1 to 72, may be
specified for this salvo position. The preset scene specified is
called automatically when the camera associated with this
salvo position is called. If a preset is not desired, enter a zero
in this field.
AUX (Auxiliary) - If the camera site is equipped with a
Receiver that has Auxiliary relays, an auxiliary can be
activated automatically by this salvo position. The number and
type of auxiliary functions at a site depends on the options
installed in the camera Receiver. If no auxiliary is desired,
enter a zero in this field.
CN (Connect Next) - Connect Next selects the next camera
position in the menu for simultaneous callup to the next
contiguous system monitor, thereby forming the salvo.
A selection of Yes (“Y”), No (“N”), or Salvo (“S”) can be
chosen for Connect Next.
If “Y” is selected, the next camera in the menu is included in
the salvo, and is called to the next contiguous monitor.
If “N” is selected, the salvo stops at this camera position.
If “S” is selected, another System Salvo is called and this
salvo stops at this position.
PREVIOUS MENU - Returns to the SYSTEM menu, page 4-
3.
MENU PROGRAMMING AD1024
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 SYSTEM OPTIONS
7 MONITOR STATUS
RETURN MAIN
SET SYSTEM SALVOS
SALVO - 01
POS CAM PRE AUX CN
1 0001 00 0 - Y
2 0002 02 2 ON Y
3 0003 03 3 ON Y
4 0004 04 4 ON Y
5 0005 70 3 ON Y
6 0006 00 0 - Y
.
.
.
16 0016 72 1 OFF N