PORTS
The PORT menu is used to configure baud rates, data bits,
parity, stop bits, and port use for each of the ten RS-232 ports
of the LOCAL AD1024 CPU.
Note: Once the connections and selections for the port have
been made, do not change the settings, i.e., baud rate,
parity, or port use, unless the connected devices (baud
rate, parity) are changed as well.
To select a Port Number:
1. Place the cursor at the PORT line at the top of the menu.
2. Enter the desired port number (1 - 10) on the keypad.
3. Press the ENTER key.
All fields in the menu are toggle fields; press the ENTER key
to cycle through the possible selections in each field.
BAUD - Selects the RS-232 baud rate for the port.
1. Place the cursor on the BAUD line of the menu.
2. Press the ENTER key to cycle through the baud rates.
Press the NEXT key to accept the displayed selection.
or
Enter the number which corresponds to the desired baud
rate and press the ENTER key to lock in the selection.
1 = 300
2 = 1200
3 = 2400
4 = 4800
5 = 9600
DATA BITS - Selects the number of data bits.
1. Place the cursor on the DATA BITS line.
2. Press the ENTER key to toggle the selections, 7 or 8.
Press the NEXT key to accept the displayed selection.
PARITY - Selects the data parity.
1. Place the cursor on the PARITY line.
2. Press the ENTER key to cycle through the selections.
Press the NEXT key to accept the displayed selection.
or
Enter the number which corresponds to the desired
parity and press the ENTER key to lock in the selection.
1 = NONE
2 = ODD
3 = EVEN
STOP BITS - Selects the number of stop bits.
1. Place the cursor on the STOP BITS line.
2. Press the ENTER key to toggle the selections, 1 or 2.
Press the NEXT key to accept the displayed selection.
PORT USE - Defines the use or type of device connected to
the port. See page 4-21 for explanation of the Port Use types.
1. Place the cursor on the PORT USE line.
2. Press the ENTER key to cycle through the port
selections. Press the NEXT key to accept the displayed
selection.
or
Enter the number which corresponds to the desired port
use and press the ENTER key to lock in the selection.
1 = ALARM
2 = KEYBOARD
3 = TERMINAL
4 = PRINTER
5 = AUX
6 = VIDEO LOSS
7 = SATELLITE
The RETURN MAIN line of the Port menu returns to the
Main Selection menu, page 4-2.
4-22
MENU PROGRAMMING AD1024
PORT - 01
BAUD - 1200
DATA BITS - 8
PARITY - NONE
STOP BITS - 1
PORT USE - KEYBOARD
RETURN MAIN