PRE (Preset)
If a preset is desired for this camera:
1. Move the cursor to the PRE column and desired ACN.
2. Enter the desired preset number (from 1 to 72). Zero
represents no preset call for this entry.
3. Press the ENTER key.
Note: If the CN field is set to “S”, do not enter a preset scene.
Example: To set preset 05 for camera 17 (for ACN 0007).
ALARM CONTACT SETUP
ACN CAM DWL PRE AUX CN
0001 0001 02 00 0 - N
0002 0002 02 00 0 - N
0003 0003 02 00 0 - N
0004 0004 02 00 0 - N
0005 0005 02 00 0 - N
0006 0006 02 00 0 - N
0007 0017 30 05 1 ON N
0008 0008 02 00 0 - N
.
.
0016 0016 02 00 0 - N
PREVIOUS MENU
AUX (Auxiliary)
If an auxiliary action is desired for an ACN entry:
1. Move the cursor to the AUX column and desired ACN.
2. Press the ENTER key to cycle through the auxiliary
actions. Press the NEXT key to accept the selection.
or
Enter one of the following auxiliary selection numbers
and press the ENTER key.
1 = 1 ON 5 = 1 OFF
2 = 2 ON 6 = 2 OFF
3 = 3 ON 7 = 3 OFF
4 = 4 ON 8 = 0 - (no action)
Note: If the CN field is set to “S”, do not enter an auxiliary
action.
Example: To set Aux 1 ON for camera 17 (for ACN 0007).
ALARM CONTACT SETUP
ACN CAM DWL PRE AUX CN
0001 0001 02 00 0 - N
0002 0002 02 00 0 - N
0003 0003 02 00 0 - N
0004 0004 02 00 0 - N
0005 0005 02 00 0 - N
0006 0006 02 00 0 - N
0007 0017 30 05 1 ON N
0008 0008 02 00 0 - N
.
.
0016 0016 02 00 0 - N
PREVIOUS MENU
Note: Different ACN entries may be associated with the same
camera, with different auxiliary and preset scene calls. If
more than one of these alarm contacts is received during the
same time period, the system will activate each preset and
auxiliary for the same camera in the order that the alarms
are received, stopping at the preset and auxiliary of the last
received alarm contact. In this instance, the operator may
not see the first preset or auxiliary action(s).
4-14