Programming Alarm Contacts
Note: The following contact programming procedures are for
AD1678CM keyboards only. For other keyboards, use
the Monitor/Contact Access menu, page 4-27.
To program a contact for a monitor:
1. Call the desired monitor.
2. Enter the alarm contact number (ACN) to be associated to
this monitor for displays.
3. Press the ARM button in the keyboard Camera group.
The contact number with the letter “E”, for enabled, is
displayed in the on-screen Status Line for five seconds to
verify the contact has been armed for that monitor.
For Example: Contact number 21 was programmed for the
monitor by entering the number “21” on the enter pad and
pressing the Camera ARM button. This will result in the
on-screen display shown in Figure 3-2.
Note: Monitors used for salvo alarm response should not be
programmed for individual alarm contacts (see page 4-27).
To disarm a contact for a monitor:
1. Call the monitor.
2. Enter the contact number to be disarmed.
3. Press the OFF button in the keyboard Camera group.
The contact number with the letter “D”, for disarmed, is
displayed on the screen for five seconds to verify the contact
has been disarmed for that monitor. That alarm input will no
longer be displayed until the associated remote alarm contact
has been deactivated and subsequently reactivated.
Note: Contacts cannot be disarmed while they are active.
Audio Alarm Indicators
AD1678CM and AD2078 keyboards can be programmed to
provide an audio tone when an alarm is received. When the
audio tone is enabled at a keyboard and an armed monitor is
called to that keyboard, the audio tone is sounded when the
associated alarm is first received, for less than five seconds.
The default setting is audio enabled (ON) for all keyboards.
There are three ways to enable or disable this audio indicator:
For a Keyboard, For a Port, and System Wide.
For a Keyboard - When sound is turned off at a keyboard,
the AD1650B will transmit the sound character to all
keyboards but a keyboard that is off will not sound the
audio tone.
To Turn Audio ON for that Keyboard only:
1. Call the armed monitor.
2. Enter the number “9” on the keypad.
3. Press the auxiliary ON pushbutton.
To Turn Audio OFF for that Keyboard only:
1. Call the armed monitor.
2. Enter the number “9” on the keypad.
3. Press the auxiliary OFF pushbutton.
For a Port - When the audio is turned off for a port, the
AD1650B will no longer transmit the sound character to
that particular keyboard port.
To Turn Audio ON for a Port:
1. Enter the number “48” on the keypad.
2. Press the F2 button.
To Turn Audio OFF for a Port:
1. Enter the number “47” on the keypad.
2. Press the F2 button.
System Wide - When the audio is turned off system wide, the
AD1650B will no longer transmit the sound character to
any keyboard port.
To Turn Audio ON System Wide:
1. Enter the number “46” on the keypad.
2. Press the F2 button.
To Turn Audio OFF System Wide:
1. Enter the number “45” on the keypad.
2. Press the F2 button.
3-6
001 -
21E
American
Dynamics
10-15-93
10:27:53
Contact 21 Armed
for this Monitor
Figure 3-2 - On-Screen Contact Arming Display