American Dynamics AD1650B Instrucciones de operaciones Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
Alarm Monitor/Contact (ALM ) callup
Separate Monitor/Contact Tables can be programmed to define
which alarm contacts are armed for each monitor in the system
(see page 4-27 for Monitor/Contact Table programming). The
first table, Table 0, defines the current (active) system
monitor/contact arming state. Monitor/Contact Tables 1 - 4 are
pre-programmed tables that are called to the current
Monitor/Contact Table by the Alarm Monitor/Contact (ALM)
settings of the Set Event Timer menu.
Each entry in the ALM line identifies a Monitor/Contact Table
that is called at the specified Event time (TIME) on the
indicated day of the week (S - S). The table called up becomes
the active system Monitor/Contact Table (Table 0), replacing
the current monitor/contact arming state. The ALM entries for
a new Event Timer are defaulted to zero, no Monitor/Contact
Table callups.
To define Monitor/Contact Table callup by an Event Timer:
1. Move the cursor to the day of week in the ALM line.
2. Enter the Monitor/Contact Table number (0 - 4) desired for
callup at the specified day and Event time.
0 = no callup, use the current Monitor/Contact Table.
1 = calls up the Monitor/Contact Table 1.
2 = calls up the Monitor/Contact Table 2.
3 = calls up the Monitor/Contact Table 3.
4 = calls up the Monitor/Contact Table 4.
3. Press the ACK key.
Example: The following Event Timer is set for 7:11, to callup
System Tours 01 through 06 to Monitor 001 on Sunday
through Friday respectively, and to callup Monitor/Contact
Table 1 on Monday and Table 2 on Saturday.
SET EVENT TIMERS
TIME - 07:11
DAY OF WEEK
MONSMTWTFS
001 01 02 03 04 05 06 00
002 00 00 00 00 00 00 00
003 00 00 00 00 00 00 00
004 00 00 00 00 00 00 00
ALM 0100002
PREVIOUS MENU
The PREVIOUS MENU line in the SET EVENT TIMERS
menu returns to the EVENT TIMER menu, page 4-10.
NEXT TIMER
Place cursor on the NEXT TIMER line and press the ACK key
to scroll through the programmed Event Timers.
Each programmed Event Timer shows the time of the event
and its disabled/enabled state.
CLEAR TIMER
This command deletes the current Event Timer.
1. Place cursor on CLEAR TIMER line.
2. Press the ACK key. Time reverts back to 24:00 with an
ILLEGAL TIME display.
ENABLE/DISABLE TIMER
Initially, the Event Timer is in a disabled state. You can either
ENABLE or DISABLE the timer. The selected menu line in
the EVENT TIMER menu is always opposite to the current
state. The ACK key switches between the two states and
toggles the menu line.
DISABLE TIMER
This command disables the Event Timer, but retains data.
1. Place cursor on the DISABLE TIMER line.
2. Press the ACK key. The Event Timer is now disabled
and the menu line changes to ENABLE TIMER.
ENABLE TIMER
This command enables the Event Timer.
1. Place the cursor at the ENABLE TIMER line.
2. Press the ACK key. The Event Time is now enabled
and the menu line changes to DISABLE TIMER.
CHANGE TIMER TO HH:MM
This command changes the time for the current Event Timer.
1. Place cursor on CHANGE TIMER TO HH:MM line.
2. Enter the correct hour.
3. Press the ACK key. The correct hour appears in the upper
left-hand timer display.
4. Enter the correct minute.
5. Press the ACK key. The correct minute appears in the
upper left-hand timer display.
PREVIOUS MENU - This command in the EVENT TIMER
menu returns to the SYSTEM menu, page 4-3.
4-11