SET SYSTEM TOURS
A System Tour is a programmable sequence of cameras that
can be called by a user to be displayed on the called monitor,
or called by Event Timers to any monitor. The SET SYSTEM
TOURS menu permits programming of 64 System tours. Each
tour includes 64 entries. Each entry contains a camera number,
dwell time, preset, auxiliary, and connect next.
The SET SYSTEM TOURS menu has eight pages, with eight
entries per page. See page 4-3 for menu paging instructions.
The tour being programmed is identified in the TOUR line
below the menu title.
ENT (Entry) - Each of the 64 entries in a tour consists of a
camera number, dwell time, preset number, auxiliary number,
and a connect next designation (for salvos). Each tour entry is
unique and the same camera (with different dwell times,
presets, etc.) may be entered as many times as desired.
CAM (Camera) - A camera number is associated with each
tour entry. If the CN field is an “S” or “T” the tour entry is
associated with a System Salvo or another System Tour, that is,
the CAM number is a System Salvo or System Tour number.
DWL (Dwell Time) - The dwell time is the length of time the
camera is displayed on the monitor before switching to the
next tour entry. The dwell time may be from 1 to 60 seconds;
an entry of 61 will “HOLD” the current camera displayed.
PRE (Preset) - If the camera site is equipped for preset scenes
(see page 3-3) a preset scene, from 1 to 72, may be specified
for this tour entry. The preset scene specified is called
automatically when the camera associated with this entry is
called. If a preset is not desired, enter a zero in this field.
AUX (Auxiliary) - If the camera site is equipped with a
Receiver that has Auxiliary relays, an auxiliary can be
activated automatically by this tour entry. The number and
type of auxiliary functions at a site depends on the options
installed in the camera Receiver. If no auxiliary is desired,
enter a zero in this field.
CN (Connect Next) - Connect Next selects the next camera
entry of the tour for simultaneous callup to the next contiguous
monitor, thereby forming a “Scratch Pad” Salvo call. This
salvo calls up a set of cameras to contiguous monitors for the
dwell time specified by the first camera entry.
A selection of No (“N”), Yes (“Y”), Salvo (“S”), or Tour (“T”)
can be chosen for Connect Next.
• If “N” is selected, the Connect Next feature is not initiated.
The next tour entry is selected for display after the specified
dwell time.
• If “Y” is selected, the Connect Next feature calls the next
tour entry to the next contiguous monitor; a Dwell Time
cannot be programmed for the next entry.
• If “S” is selected, a pre-programmed System Salvo is called.
The System Salvo number is specified in the CAM entry.
• If “T” is selected, another System Tour is called. The
System Tour number is specified in the CAM entry. This
selection links a number of tours together to form a larger
camera sequence.
Note: A tour cannot call itself.
The PREVIOUS MENU line returns to the SYSTEM menu,
page 4-3.
4-5
AD1650B MENU PROGRAMMING
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
RETURN MAIN
SET SYSTEM TOURS
TOUR - 01
ENT CAM DWL PRE AUX CN
01 001 02 01 1 ON N
02 002 02 02 2 ON N
03 003 02 03 3 ON N
04 004 02 04 4 ON N
05 005 02 05 1 OFF N
06 006 02 06 2 OFF N
07 007 02 07 3 OFF N
08 008 02 08 0 N
PREVIOUS MENU