MONITOR/CONTACT ACCESS
The MONITOR/CONTACT ACCESS menu defines which
alarm contacts are associated to each monitor in the system.
Five Monitor/Contact Tables can be programmed by this menu,
providing different Monitor/Contact associations. The first
table, Table 0, is the current (active) system Monitor/Contact
arming status. Monitor/Contact Tables 1 - 4 are stored tables
that can be written into (called to) the current Monitor/Contact
arming table by Event Timers only (page 4-10).
The Monitor Contact Table menu has multiple pages with eight
ACN’s per page vertically, and four monitors per page
horizontally. Refer to page 4-3 for menu paging instructions.
The title line of the Monitor/Contact Table menu indicates the
table which is being programmed. If this line displays two
dashes ( - - ), the current (active) table is being programmed; if
a number (1 to 4) is displayed, the corresponding stored
Monitor/Contact table is being programmed.
The above example indicates that Monitor Contact table 1:
Alarm Contact 003 will activate monitor 7's Arm Type
Alarm Contact 004 will activate monitor 8's Arm Type
Alarm Contact 006 will activate monitor 5's Arm Type
See the Appendix, pages A-3 to A-7, for further description of
Alarm Contact Arming.
The Monitor/Contact Tables are set default to N, no contacts
are associated with any monitors.
To select a Monitor/Contact Table for programming:
1. Place the cursor on the MON CONTACT TABLE title line.
2. Enter the table number, 1-4, on the keypad. If no number is
entered, the current active table is selected.
3. Press the ACK key.
To change the alarm contact association of the selected table:
1. Position the cursor to the alarm contact (ACN) and monitor
entry to be changed.
2. Press the ACK key. Each time the ACK key is pressed the
setting toggles between: Y = ACN is associated to this
monitor, N = ACN is not associated.
3. Repeat steps 1 and 2 for any additional changes desired.
Note: DO NOT mix monitor salvos in alarm contact arming.
Monitors used for salvo alarms should not be programmed
for individual alarm contacts.
* Monitors associated to individual alarm contacts should
not be included in salvos that are armed to alarm contacts
(via either the Connect Next or Salvo selections in the Set
Alarm Contacts menu, page 4-12). Such monitors may be
armed to one or more other individual alarm contacts only.
* Monitors included in salvos armed to alarm contacts
(via the Set Alarm Contacts menu, page 4-12) should not be
armed to individual alarm contacts. Such monitors may be
included in other salvos armed for alarm contacts, as long
as all salvos are of equal length (i.e., the same number of
monitors in the salvos).
Note: When arming alarm contacts to a monitor block, arm
the contacts to the first monitor of the block only. DO NOT
arm any contacts to the remaining monitors of a block.
Position the cursor at the PREVIOUS MENU line and press
the ACK key to return to the main ACCESS Menu, page 4-22.
4-27
AD1650B MENU PROGRAMMING
ACCESS
1. KEYBOARD/MONITOR
2. KEYBOARD/CAMERA VIEW
3. KEYBOARD/CAMERA CONTROL
4. MONITOR/CAMERA ACCESS
5. MONITOR/CONTACT ACCESS
RETURN MAIN
MON CONTACT TABLE - 1
MONITOR
ACN 05 06 07 08
001 NNNN
002 NNNN
003 N N Y N
004 N N N Y
005 NNNN
006 Y N N N
007 NNNN
008 NNNN