SET ALARM CONTACTS
The SET ALARM CONTACT menu is used to associate
cameras to contacts. A maximum of 512 entries are allowed.
Each Alarm Contact Number (ACN) is associated with a
camera number, a dwell time, and if desired a preset, an
auxiliary, and a connect next item for salvo call on alarm.
The Set Alarm Contact menu has 64 pages, with eight ACNs
per page. Refer to page 4-3 for menu paging instructions.
ACN (Alarm Contact Number) - Each of the 512 ACN entries
is unique and consists of a camera number, dwell time, camera
preset, auxiliary, alarm title, and connect next that are activated
when this contact is received. Since each entry is unique, a
camera may be entered for different ACN’s as required with
different dwell times, different presets, etc.
CAM (Camera) - This identifies the camera that is called to
the monitor armed for this ACN (Monitor/Contact Access
Menu, page 4-27) when the alarm contact is received. If the
CN field is “S”, the CAM entry is associated with System
Salvos, and the Camera number entry is a System Salvo
number.
DWL (Dwell Time) - Dwell Time sets the amount of dwell for
the camera. The dwell time may be from 1 to 60 seconds in
one second increments. An entry of 61 “HOLDs” the current
camera displayed.
PRE (Preset) - If the camera is equipped with motorized
pan/tilt and lens with feedback potentiometers, automatic
preset scenes may be defined. If presets have been defined for
the camera, the preset scene specified in this entry is called
automatically when the camera is displayed on alarm receipt.
If a preset is not desired, enter a zero.
AUX (Auxiliary) - If the camera site is equipped with a
Receiver that has Auxiliary relays, an auxiliary can be
activated automatically on alarm receipt. If no auxiliary action
is desired, enter a zero in this field.
CN (Connect Next) - Connect Next selects the next camera in
the table for simultaneous callup when the alarm contact is
received. “N” (No), “Y” (Yes), “S” (Salvo), or “W” (Wired
Set) can be selected for Connect Next.
• If “N” is selected, the Connect Next feature is not initiated.
The next ACN entry in the table is used for an alarm contact.
• If “Y” is selected, the Connect Next feature calls the next
table entry to the next contiguous monitor, for the dwell time
specified by the first camera entry; the next ACN is no
longer active and cannot be used for an alarm contact. (The
last entry of a Y set must have an “N” or “S” CN entry.)
• If “S” is selected, a pre-programmed System Salvo is called.
The System Salvo number is specified in the CAM entry.
• If “W” is selected, the Connect Next feature activates all
ACN entries in a contiguous set when that alarm contact is
received; each ACN entry in the contiguous set is still active
for the associated alarm contact. (The last entry of a Wired
set must have an “N” or “S” CN entry.)
In addition, each CN selection in a contiguous Wired set
may include an “*” symbol. This indicates that when the
associated ACN is manual Acknowledged, all alarm contacts
in that Wired set are cleared.
The PREVIOUS MENU line of the SET ALARM CONTACTS
menu returns to the SYSTEM menu, page 4-3.
4-12
MENU PROGRAMMING AD1650B
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
RETURN MAIN
ALARM CONTACT SETUP
ACN CAM DWL PRE AUX CN
001 001 02 00 0 - N
002 002 02 00 0 - N
003 003 02 00 0 - N
004 004 02 00 0 - N
005 005 02 00 0 - N
006 006 02 00 0 - N
007 007 02 00 0 - N
008 008 02 00 0 - N