PROGRAMMING A SALVO
To select a System Salvo for programming:
1. Position cursor to the SALVO line in the menu.
2. Enter the desired salvo number (from 1 to 16).
3. Press the ACK key.
See page 4-3 for cursor movement instructions.
CAM (Camera)
To add or change a camera in a salvo:
1. Move the cursor to the CAM column and appropriate salvo
position line.
2. Enter the desired camera number (1 - 128 for Real camera
numbers or 1 - 999 for Pseudo numbers). If the CN field is
set to “S”, enter a System Salvo number (1 - 16).
3. Press the ACK key.
Note: To eliminate a camera from a salvo, press the ACK key
without entering a number in the CAM field.
PRE (Preset)
If a preset scene is desired for the camera:
1. Move the cursor to the PRE column and desired camera
position line.
2. Enter the preset number (1 - 72) to call for this camera.
Zero represents no preset call for this entry. If the CN field
is set to “S”, do not enter a preset number.
3. Press the ACK key.
AUX (Auxiliary)
If an auxiliary action is desired for an entry:
1. Move the cursor to the AUX column and desired camera
position line.
2. Press the ACK key to cycle through the AUX selections.
Press the NEXT key to accept the displayed selection.
or
Enter one of the following numbers and press the ACK key.
The auxiliary selection will appear in the AUX column.
1 = 1 ON 5 = 1 OFF
2 = 2 ON 6 = 2 OFF
3 = 3 ON 7 = 3 OFF
4 = 4 ON 8 = 0 - (no action)
If the CN field is set to “S”, do not enter an auxiliary action.
CN (Connect Next)
To include the next camera, or another System Salvo:
1. Move the cursor to the CN column for the desired position.
2. Press the ACK key to cycle through the CN selections.
Press the NEXT key to accept the displayed selection.
or
Enter one of the following numbers and press the ACK key.
The selection will display in the CN column entry.
1 = N, no connect next
2 = Y, connect to the next entry
3 = S, call a System Salvo
All positions in a System Salvo should have the CN entry set
to Y except the last entry, which is set to N or S.
On the first Salvo entry line, if an actual camera number
matches the salvo number, only “Y” or “N” can be selected.
If a System Salvo is selected (S), the CAM number for this
position must be set to the desired System Salvo number.
If Pseudo numbers are used, the CAM number switches
between Pseudo numbers when N or Y is selected, and Real
numbers when S is selected.
Example: For a five camera salvo, set position 5 to Camera
number 17, Preset number 70, Auxiliary 3 ON, and CN to
N indicating the last camera in System Salvo 01.
SET SYSTEM SALVOS
SALVO - 01
POS CAM PRE AUX CN
01 001 00 0 - Y
02 002 02 0 - Y
03 003 03 0 - Y
04 004 04 0 - Y
05 017 05 3 ON N
06 006 06 0 - N
07 007 07 0 - N
08 008 08 0 - N
PREVIOUS MENU
CALLING A SYSTEM SALVO
To call a System Salvo from a keyboard:
1. Call the first monitor for the first camera in the salvo.
2. Enter the desired System Salvo number (1 - 16).
3. Press the SALVO key. The cameras, presets, and
auxiliaries associated with that salvo will be displayed on
the selected monitor, up to the nth contiguous monitor.
4-9