MONITOR
The MONITOR menu is used to review and change each
monitor's setup programming.
To select a Monitor for review or programming:
1. Place the cursor on the MONITOR line.
2. Enter the monitor number (1 - 16) on the keypad.
3. Press the ACK key to move to the ARM TYPE field.
ARM TYPE - The Arm Type indicates the current alarm
display, queuing, and removal method armed for this monitor.
The available monitor Arm Types are listed in the table to the
right. The default value for all monitors is DIS (Disarmed).
To set or change a monitor Arm Type:
1. Position the cursor to the ARM TYPE field.
2. Press the ACK key to cycle through the Arm Types until the
desired Arm Type is shown, then press the NEXT key.
or
Enter the code number for the desired Arm Type (see table)
and press the ACK key.
For arming codes 13 - 15, the second (Sequence) monitor is
selected automatically (the next numeric system monitor)
when the first (Hold) monitor is armed.
The cursor moves to the BLOCK number field (##) if a block
arming code is selected (7 - 12), and a new block number (the
next sequentially available block number, from 1 - 16) is
displayed. If a non-block arming code is selected the BLOCK
number defaults to a pound symbol (##) and the cursor moves
to the ACK field.
Note: ARM TYPE cannot be set or changed if any alarm
contacts are active.
Monitor Arming Codes
Code Description Arm Type
1 Sequence, Instant Clear SSI
2 Sequence, Auto Clear (after 20 seconds) SSA
3 Sequence, Manual Clear (ACK key) SSM A*
4 Hold, Instant Clear SHI
5 Hold, Auto Clear SHA
6 Hold, Manual Clear SHM A*
7 Block Sequence, Instant Clear BSI
8 Block Sequence, Auto Clear BSA
9 Block Sequence, Manual Clear BSM A*
10 Block Hold, Instant Clear BHI
11 Block Hold, Auto Clear BHA
12 Block Hold, Manual Clear BHM A*
First Monitor Second Mon
Arm Type Arm Type
13 Hold and Sequence,
Instant Clear DHI DSI
14 Hold and Sequence,
Auto Clear DHA DSA
15 Hold and Sequence,
Manual Clear DHM A* DSM A*
16 Disarmed DIS
* Manual Clear/Acknowledge feature is always enabled.
The Manual Clear/Acknowledge feature can be enabled or
disabled for any Instant Clear and Auto Clear arming code via
the ACK entry of the Monitor menu (see next page). When
enabled, the ACK key can also be used to clear alarms from
this monitor (see Acknowledging Alarms, page 2-6).
The Monitor Arming Code can also be set for an individual
monitor by keyboard commands, page 3-5.
See the Appendix, pages A-3 to A-7, for further definition of
Alarm Programming and Monitor Arming Codes.
4-16
MENU PROGRAMMING AD1650B
MONITOR - 01
ARM TYPE - ## ACK -
TOUR - - -
DATE/TIME -
TITLE DISPLAY -
CAM TITLE LCK -
MON TITLE LCK -
DISPLAY STATUS -
RETURN MAIN
Vista de pagina 37