PORT
The PORT menu is used to configure baud rates, data bits,
parity, stop bits, and port use for each of the four RS-232 ports
on the rear of the AD1650B.
Note: Once the selections for a port have been made, do not
change the settings (Baud, Parity, etc.) unless the
connected devices are changed as well.
To select a Port Number:
1. Place the cursor at the PORT line at the top of the menu.
2. Enter the desired port number (1 - 4) on the keypad.
3. Press the ACK key.
All fields in the menu are toggle fields; press the ACK key to
cycle through the possible selections in each field.
BAUD - Selects the RS-232 baud rate for the port.
1. Place the cursor on the BAUD line of the menu.
2. Press the ACK key to cycle through the baud rates. Press
the NEXT key to accept the displayed selection.
or
Enter the number which corresponds to the desired baud
rate and press the ACK key to lock in the selection.
1 = 300
2 = 1200
3 = 2400
4 = 4800
5 = 9600
DATA BITS - Selects the number of data bits.
1. Place the cursor on the DATA BITS line.
2. Press the ACK key to toggle the selections, 7 or 8. Press
the NEXT key to accept the displayed selection.
PARITY - Selects the data parity.
1. Place the cursor on the PARITY line.
2. Press the ACK key to cycle through the parity selections.
Press the NEXT key to accept the displayed selection.
or
Enter the number which corresponds to the desired parity
and press the ACK key to lock in the selection.
1 = NONE
2 = ODD
3 = EVEN
STOP BITS - Selects the number of stop bits.
1. Place the cursor on the STOP BITS line.
2. Press the ACK key to toggle the selections, 1 or 2. Press
the NEXT key to accept the displayed selection.
PORT USE - Defines the use or type of device connected to
the port. See page 4-21 for explanation of the Port Use types.
1. Place the cursor on the PORT USE line.
2. Press the ACK key to cycle through the port selections.
Press the NEXT key to accept the displayed selection.
or
Enter the number which corresponds to the desired port use
and press the ACK key to lock in the selection.
1 = ALARM
2 = KEYBOARD
3 = TERMINAL
4 = PRINTER
5 = AUX
The RETURN MAIN line of the PORT menu returns to the
the Main Selection menu, page 4-2.
4-20
MENU PROGRAMMING AD1650B
PORT - 01
BAUD - 1200
DATA BITS - 8
PARITY - NONE
STOP BITS - 1
PORT USE - KEYBOARD
RETURN MAIN