Vista de pagina 29
SET SYSTEM SALVOS
A System Salvo is a group of cameras that can be called
simultaneously to a contiguous group of monitors. A salvo can
be called by keyboard commands, from a System Tour or
another System Salvo, or on alarm receipt when included in an
Alarm Contact setup. The SET SYSTEM SALVOS menu
permits programming of 16 separate System Salvos. The
maximum number of cameras in a System Salvo is eight. Note
that System Salvos can be nested within other System Salvos.
The SET SYSTEM SALVOS menu has one page, with eight
camera positions included in the page.
The salvo being programmed is identified by the SALVO line
below the title line of the menu.
POS (Position) - The salvo position refers to the order of the
cameras displayed on the contiguous monitors. Each position
of the salvo identifies a camera with an optional preset scene
and auxiliary action for this camera.
For Example: If a System Salvo containing six cameras is
called to monitor 11, the first salvo camera is shown on
monitor 11, the second camera on monitor 12, and so on, up
to the last camera on monitor 16.
CAM (Camera) - A camera number is associated with each
salvo position. This camera is displayed on the next
contiguous monitor. If the CN field is “S”, the CAM entry is
associated with another System Salvo, and the Camera number
is a System Salvo number (a nested Salvo).
PRE (Preset) - If the camera site is equipped for preset scenes
a preset scene, from 1 to 72, may be specified for this salvo
position. The preset scene specified is called automatically
when the camera associated with this salvo position is called.
If a preset is not desired, enter a zero in this field.
AUX (Auxiliary) - If the camera site is equipped with a
Receiver that has Auxiliary relays, an auxiliary can be
activated automatically during a salvo. The number and type
of auxiliary functions at a site depends on the options installed
in the camera Receiver. If no auxiliary action is desired, enter
a zero in this field.
CN (Connect Next) - Connect Next selects the next camera in
the table for simultaneous callup to the next contiguous
monitor, thereby forming the salvo. A selection of Yes (“Y”),
No (“N”), or Salvo (“S”) can be chosen for Connect Next.
If “Y” is selected, the next camera in the table is included in
this salvo.
If “N” is selected, the salvo stops at this camera entry.
If “S” is selected, another System Salvo is called and this
salvo stops at this entry.
The PREVIOUS MENU line of the SET SYSTEM SALVOS
menu returns to the SYSTEM menu, page 4-3.
4-8
MENU PROGRAMMING AD1650B
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
RETURN MAIN
SET SYSTEM SALVOS
SALVO - 01
POS CAM PRE AUX CN
1 001 00 0 - Y
2 002 02 2 ON Y
3 003 03 3 ON Y
4 004 04 4 ON Y
5 005 70 3 ON Y
6 006 00 0 - Y
7 007 00 0 - Y
8 008 72 1 OFF N
PREVIOUS MENU