PROGRAMMING ALARM CONTACTS
Alarm Contact Numbers 1 to 128, 129 to 256, 257 to 384, and
385 to 512 are defaulted to cameras 1 through 128,
respectively. Dwell Times are defaulted to two seconds.
To select an Alarm Contact for programming:
- Move the cursor to the desired Alarm Contact Number
(ACN) line of the menu (from 1 to 512).
See page 4-3 for cursor movement and paging instructions.
CAM (Camera)
To associate a specific camera with an ACN:
1. Move the cursor to the CAM column and the appropriate
ACN entry.
2. Enter the desired camera number (1 - 128 for Real camera
numbers or 1 - 999 for Pseudo numbers). If the CN field is
set to “S”, enter a System Salvo number.
Note: If Pseudo numbers are used, the CAM number switches
between Pseudo numbers when N, Y, or W is selected and
Real numbers when S is selected for the CN field.
3. Press the ACK key.
DWL (Dwell Time)
T
o set a dwell time for the camera:
1. Move the cursor to the DWL column and the appropriate
ACN entry.
2. Enter the desired dwell time (from 1 to 60) in seconds. If
61 is entered, the camera is set to a Hold at this tour entry.
3. Press the ACK key.
CAM and DWL Example: Set ACN007 to call camera 17
with a dwell time of 30 seconds.
ALARM CONTACT SETUP
ACN CAM DWL PRE AUX CN
001 001 02 00 0 - N
002 002 02 00 0 - N
003 003 02 00 0 - N
004 004 02 00 0 - N
005 005 02 00 0 - N
006 006 02 00 0 - N
007 017 30 00 0 - N
008 008 02 00 0 - N
PREVIOUS MENU
If presets, aux, or salvo (CN) actions are not required, repeat
the preceding CAMERA and DWELL TIME instructions.
PRE (Preset)
If a preset scene is desired for this camera:
1. Move the cursor to the PRE column and associated ACN.
2. Enter the desired preset number (from 1 to 72). Zero
represents no preset call for this entry. If the CN field is set
to “S”, do not enter a preset number.
3. Press the ACK key.
AUX (Auxiliary)
If an auxiliary action is desired for an ACN entry:
1. Move the cursor to the AUX column and associated ACN.
2. Press the ACK key to cycle through the AUX selections.
Press the NEXT key to accept the displayed selection.
or
Enter one of the following numbers and press the ACK key.
The auxiliary selection will appear in the AUX column.
1 = 1 ON 5 = 1 OFF
2 = 2 ON 6 = 2 OFF
3 = 3 ON 7 = 3 OFF
4 = 4 ON 8 = 0 - (no action)
If the CN field is set to “S”, do not enter an auxiliary action.
Example: Set preset 05 and AUX 1 ON for ACN 007.
ALARM CONTACT SETUP
ACN CAM DWL PRE AUX CN
001 001 02 00 0 - N
002 002 02 00 0 - N
003 003 02 00 0 - N
004 004 02 00 0 - N
005 005 02 00 0 - N
006 006 02 00 0 - N
007 017 30 05 1 ON N
008 008 02 00 0 - N
PREVIOUS MENU
Note: Different ACN entries may be associated with the same
camera, using different preset scenes and auxiliary actions.
If more than one of these alarms is received during the same
time period, the system will activate each preset and
auxiliary for the same camera in the order that the alarms
are received, stopping at the last received alarm contact. In
this instance, the operator may not see the first preset or
auxiliary action.
4-13