SET EVENT TIMERS
Event Timers permits automatic callup of System Tours and/or
Alarm Monitor Contact Tables. Each one of the automatic
callups is referred to as an Event.
The EVENT TIMER menu is used to identify each Event and
to program each Event for automatic callups. A maximum of
35 Events are available for programming. Each Event can be
programmed for individual System Tour and Alarm Contact
Table callups on different days of the week.
An Event Timer (“Event”) is created by entering a new time in
the first line. If the Event is a new time the word “NEW” is
displayed. If the Event already exists, either the word
“ENABLED” or “DISABLED” is displayed.
To create a new Event Timer, or edit an existing Timer:
1. Move the cursor to the time location under the menu title.
2. Enter the hours (for example, 07) and press the ACK key.
Note: Enter time in 24-hour format.
3. Enter the minutes (for example, 11) and press the ACK key.
This moves the cursor to the EDIT TIMER line item in the
EVENT TIMER menu.
Note: A maximum of 35 Event Timers can be programmed.
If a time is entered for a 36th event, the message “EVENT
TABLE FULL” is displayed. An existing Event Timer
can be cleared to make room for a newly created table (see
CLEAR TIMER menu command, page 4-11).
EDIT TIMER
Place the cursor on the EDIT TIMER line and press the ACK
key to display the SET EVENT TIMERS menu. This menu is
used to program the specified Event for System Tours and
Alarm Contact Tables (ALM) callup. The SET EVENT
TIMERS menu has four pages, with four monitors per page.
Refer to page 4-3 for menu paging instructions.
Note: The day of the week must be set properly for Events to
occur as desired. See page 4-4 to set day of the week.
System Tour callup
Each entry in this table identifies a System Tour that is called
at the specified Event time (TIME) for the indicated monitor
(MON) on the indicated day of the week (S - S). The entries
for a new Event Timer are defaulted to 00, no System Tours
called to monitors.
To program a System Tour for callup by an Event Timer:
1. Move the cursor to the desired DAY OF WEEK and MON
(monitor) position.
2. Enter the System Tour number (1 - 64) to call to this
monitor at the indicated day and Event time.
Note: Entering 00 is a “no-action” command while 65 is a
“hold monitor at current camera” command.
3. Press the ACK key.
4-10
MENU PROGRAMMING AD1650B
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 MONITOR STATUS
RETURN MAIN
EVENT TIMER
07:11 DISABLED
EDIT TIMER
NEXT TIMER
CLEAR TIMER
ENABLE TIMER
CHANGE TIMER TO HH:MM
PREVIOUS MENU
SET EVENT TIMERS
TIME - 07:11
DAY OF WEEK
MONSMTWTFS
001 01 02 03 04 05 06 07
002 00 00 00 00 00 00 00
003 00 00 00 00 00 00 00
004 00 00 00 00 00 00 00
ALM0100000
PREVIOUS MENU
Comentarios a estos manuales